Interrupt 0 percent
Idle 100 percent
Model RE…3。0
Serial ID P10865704235
Start time 1999…01…01 00:04:38 UTC
Uptime 5 days; 22 hours; 56 minutes; 44 seconds
3。4。8流量检测(MONITER INTERFACE)
noc2004@BJ…BB1…T640》 monitor interface ge…6/2/0
BJ…BB1…T640 Seconds: 6 Time: 15:06:27
Interface: ge…6/2/0; Enabled; Link is Up
Encapsulation: Ethernet; Speed: 1000mbps
Traffic statistics: Current Delta
Input bytes: 26065704859449 (171539808 bps) '133893956'
Output bytes: 19680315293139 (122794288 bps) '95029764'
Input packets: 59446094571 (41530 pps) '258510'
Output packets: 83154619939 (55791 pps) '342680'
Error statistics:
Input errors: 5748203 '32'
Input drops: 0 '0'
Input framing errors: 18497234 '140'
Policed discards: 19426 '0'
L3 inpletes: 4 '0'
L2 channel errors: 0 '0'
Packet error count 0 '0'
Next='n'; Quit='q' or ESC; Freeze='f'; Thaw='t'; Clear='c'; Interface='I
MONITER INTERFACE TRAFFIC
noc2004@BJ…BB1…T640》 monitor interface traffic
Interface Input packets (pps) Output packets (pps)
so…1/1/0 44965075403 (37032) 42886893851 (34090)
so…1/2/0 32871638564 (30466) 32646361968 (31110)
so…2/0/0 8071848119 (6241) 7306889201 (6108)
so…2/2/0 5644860 (1) 17907151865 (20310)
so…5/0/0 0 (0) 0 (0)
so…5/1/0 259546630420 (222506) 310661965027 (248599)
so…5/2/0 0 (0) 0 (0)
so…6/0/0 0 (0) 0 (0)
so…6/0/1 0 (0) 0 (0)
so…6/0/2 0 (0) 0 (0)
so…6/0/3 0 (0) 0 (0)
at…6/1/0 122988071027 (96408) 95565229614 (81861)
ge…6/2/0 59442902638 (42859) 83150387428 (55533)
ge…6/3/0 43416254852 (30289) 1934183 (4)
fxp0 0 0
fxp1 91110643 79525906
fxp2 13632685 2146543
gre 0 0
Bytes=b; Clear=c; Delta=d; Packets=p; Quit=q or ESC; Rate=r; Up=^U; Down=^D
前者用于实时观察某一个指定物理端口(4。4版本可以对逻辑端口进行观察)的数据流(如OUTPUT BYTES/INPUT BYTES等)后者用于实时观察设备中所有端口流量(简化输出)
3。4。9系统日志
通过配置;系统在MESSAGE和CHASSISD默认文件中分别记录系统软件/硬件上发生的事件;通过观察此文档中的错误或告警信息;可以判断故障点。
SHOW LOG MESSAGE
noc2004@BJ…BB1…T640》 show log messages
Jul 3 08:00:00 BJ…BB1…T640 newsyslog'7608': logfile turned over
Jul 3 13:35:43 BJ…BB1…T640 inetd'314': /usr/libexec/telnetd'7619': exit status
0x100
Jul 3 13:35:57 BJ…BB1…T640 inetd'314': /usr/libexec/telnetd'7620': exit status
0x100
Jul 3 22:48:49 BJ…BB1…T640 chassisd'305': CHASSISD_BLOWERS_SPEED: blowers now
running at normal speed
Jul 3 22:49:10 BJ…BB1…T640 chassisd'305': CHASSISD_BLOWERS_SPEED: blowers bein
g set to full speed 'system warm'
Jul 3 23:54:37 BJ…BB1…T640 chassisd'305': CHASSISD_BLOWERS_SPEED: blowers now
running at normal speed
Jul 3 23:54:57 BJ…BB1…T640 chassisd'305': CHASSISD_BLOWERS_SPEED: blowers bein
g set to full speed 'system warm'
Jul 4 00:16:20 BJ…BB1…T640 chassisd'305': CHASSISD_BLOWERS_SPEED: blowers now
running at normal speed
SHOW LOG CHASSISD
noc2004@BJ…BB1…T640》 show log chassisd
Jun 18 22:13:50 send profile config sfm 3 CMD=206 fpc 5 prof 2 cnt 1 100;100 0;0
0;0
Jun 18 22:13:50 send precedence config sfm 3 CMD=207 fpc 5 0 0 0 0 0 0 3
3
Jun 18 22:13:50 send profile config sfm 3 CMD=206 fpc 6 prof 0 cnt 1 100;100 0;0
0;0
Jun 18 22:13:50 send profile config sfm 3 CMD=206 fpc 6 prof 1 cnt 1 100;100 0;0
0;0
Jun 18 22:13:50 send profile config sfm 3 CMD=206 fpc 6 prof 2 cnt 1 100;100 0;0
0;0
Jun 18 22:13:50 send precedence config sfm 3 CMD=207 fpc 6 0 0 0 0 0 0 3
3
Jun 18 22:14:33 rcv: ipc_dispatch_m160() null ipc read for args 0x91110 pipe 0xa
52c0
Jun 18 22:14:33 cleaning up sfm 3 connection
Jun 18 22:14:33 CMB cmd to SPP 3 '0xeb'; Blue LED Off '0x16'
Jun 18 22:14:33 SPP 3 Blue LED Off
Jun 18 22:14:33 send: fpc 1; sfm 3 offline
Jun 18 22:14:33 send: fpc 2; sfm 3 offline
Jun 18 22:14:33 send: fpc 5; sfm 3 offline
Jun 18 22:14:33 send: fpc 6; sfm 3 offline
Jun 18 22:14:33 fpc 1; sfm 3 offline ack
Jun 18 22:14:33 fpc 1; sfm 3 offline ack; online 0x66 online…acks 0x2
Jun 18 22:14:33 fpc 6; sfm 3 offline ack
Jun 18 22:14:33 fpc 6; sfm 3 offline ack; online 0x66 online…acks 0x42
3。4。10系统/路由协议相关(SHOW CHASSIS CRAFT…INTERFACE)
(*号代表相应指示灯点亮状态)通过软件命令远端获得设备面板运行状态。
noc2004@BJ…BB1…T640》 show chassis craft…interface
FPM Display contents:
+……………………………………………………+
|AXI520E…a…zs1 |
|Up: 49+08:33 |
| |
|Fans OK |
+……………………………………………………+
Front Panel System LEDs:
Host 0 1
………………………………………………………………
OK * *
Fail 。 。
Master * 。
Front Panel Alarm Indicators:
……………………………………………………………………………
Red LED 。
Yellow LED 。
Major relay 。
Minor relay 。
Front Panel FPC LEDs:
FPC 0 1 2 3 4 5 6 7
……………………………………………………………………